"ctrld status" reported the service manager's view and nothing else, so it
printed "Service is running" and exited 0 for a process that was alive and
registered as started but had never got past startup: no control socket, no DNS
listener, no policy applied. The one command an operator reaches for first
confirmed the service was fine while the host had no working DNS.
Probe the control server's /started endpoint before reporting success. That
endpoint only answers once the onStarted hooks have completed, which is after the
listeners are up, so a successful probe means the process is serving rather than
merely alive. A service that is registered as running but cannot confirm startup
is now reported as such, with a pointer to the log, and exits 3 - distinct from
stopped (1) and unknown (2), because it needs a different response.
A probe blocked by permissions is not evidence of a broken service: an
unprivileged caller still gets "Service is running", with a note that startup was
not verified. The probe is bounded by a short timeout so status stays fast.
Document the exit codes in the command's help, and cover the probe (ready, not
finished starting, no socket, timed out) and the classification, including that
an unreadable socket is not reported as a failure.
The not-ready verdict is only reported when the probe could have found the
daemon's socket. socketDir() is caller-relative on unix - the system directory
when writable, the caller's home otherwise - so an unprivileged "ctrld status"
looks somewhere the root-owned daemon never listened and gets ENOENT, which is
"wrong path", not "not ready". Since only darwin has an elevation PreRun and the
root-level alias has none, that is the normal invocation; reporting exit 3 there
would have told a monitoring check to restart healthy daemons. Such a caller now
gets the service manager's view with startup reported as unverified. Windows and
mobile resolve the same directory for every caller, so the verdict stays fully
available on the platform the hung start was seen on. A successful probe is still
conclusive whoever ran it.
Rollback ran os.Remove(bin) while the replacement service was still running from
that image. Windows locks a running executable, so the remove failed with
"Access is denied" - and it was fatal, so the os.Rename that restores the
previous binary never ran. The upgrade ended with the broken replacement still
installed and the working binary stranded at its _previous name.
Readiness failing is not evidence the process exited: the service manager can
report a started service whose process never became operational. So rollback now
stops the service and waits until the manager reports it stopped before touching
the executable, then cleans up DNS the way the restart path's Cleanup task does.
Restoring is now conditional on the previous binary reporting a version, since a
_previous file that exists but produces no version output would trade a service
that starts and hangs for one that cannot start at all. When it is unusable,
rollback keeps it for inspection, leaves the installed binary alone, and says so
instead of pressing on. The --version probe is bounded by a timeout so a binary
that hangs cannot hang the upgrade.
Remaining failures are reported rather than fatal, so each one says what state
the host was left in. os.Remove is retried while the path stays locked, since
Windows releases an image lock asynchronously after the process exits.
The helpers live in a new file rather than in commands.go, and the rollback is
extracted into rollbackToPreviousBinary() so it can be covered: the stop happens
while the executable is still present, an unusable previous binary is kept
without swapping or restarting, and a failed stop aborts before anything is
modified. Reversing the stop and the remove fails these tests.
The version probe is called through a variable so those tests do not have to
stage a runnable executable. Staging one is not portable: oldBin is
bin+"_previous", so a fixture named "ctrld" yields the extension-less
"ctrld_previous", which Windows refuses to execute, and a symlink to the test
binary needs a privilege Windows does not grant by default. The probe itself is
still covered against the real test binary. Production is unaffected: ctrld.exe
_previous does have an extension, and os/exec only appends PATHEXT entries when
a path has none at all - noted at binaryVersion so the suffix is not renamed
into something extension-less by accident.
This commit adds a new `ctrld log tail` subcommand that streams
runtime debug logs to the terminal in real-time, similar to `tail -f`.
Changes:
- log_writer.go: Add Subscribe/tailLastLines for fan-out to tail clients
- control_server.go: Add /log/tail endpoint with streaming response
- Internal logging: subscribes to logWriter for live data
- File-based logging: polls log file for new data (200ms interval)
- Sends last N lines as initial context on connect
- commands.go: Add `log tail` cobra subcommand with --lines/-n flag
- control_client.go: Add postStream() with no timeout for long-lived connections
Usage:
sudo ctrld log tail # shows last 10 lines then follows
sudo ctrld log tail -n 50 # shows last 50 lines then follows
Ctrl+C to stop
Add --intercept-mode flag (dns/hard/off) with configuration support,
recovery bypass for captive portals, probe-based interception
verification, VPN DNS coexistence in the proxy layer, and IPv6
loopback listener guard.
Remove standalone mDNSResponder hack files — the port 53 binding
logic is now handled within the intercept mode infrastructure.
Squashed from intercept mode development on v1.0 branch (#497).
When mDNSResponder is using port 53 on macOS, adjust listener config to
use 0.0.0.0:53, stop mDNSResponder before binding, and run cleanup on
install and uninstall so the DNS server can start reliably.
Make RFC1918 listener spawning opt-in via --rfc1918 flag instead of automatic behavior.
This allows users to explicitly control when ctrld listens on private network addresses
to receive DNS queries from LAN clients, improving security and configurability.
Refactor network interface detection to better distinguish between physical and virtual
interfaces, ensuring only real hardware interfaces are used for RFC1918 address binding.
- Add filterEmptyStrings utility function for consistent string filtering
- Replace inline slices.DeleteFunc calls with filterEmptyStrings
- Apply filtering to osArgs in addition to command args
- Improves code readability and reduces duplication
- Uses slices.DeleteFunc internally for efficient filtering
So using "ctrld stop" or service manager to stop ctrld will end up with
the same result, stopped ctrld with a working DNS, and deactivation pin
code will always have effects if set.
postRun should not restore static settings
put back validInterface check
better debug logs for os resolver init, use mutex to prevent duplicate initializations
use WMI instead of registry keys for static DNS data on Windows
use WMI instead of registry keys for static DNS data on Windows
use winipcfg DNS method
use WMI with registry fallback
go back to registry method
restore saved static configs on stop and uninstall
restore ipv6 DHCP if no saved static ipv6 addresses
do not save loopback IPs for static configs
handle watchdog interface changed for new interfaces
dont overwrite static file on start when staticdns is set to loopback
dont overwrite static file on start when staticdns is set to loopback
dont overwrite static file on start when staticdns is set to loopback
no need to resetDNS on start, uninstall already takes care of this
fix bad logger usages
patch darwin interface name
patch darwin interface name, debugging
make resetDNS check for static config on startup, optionally restoring static confiration as needed
fix netmon logging
In case of remote config validation error during start, it's likely that
there's problem with connecting to ControlD API. The ctrld daemon was
restarted in this case, but may not ready to receive requests yet.
This commit changes the error message to explicitly state that instead
of a mis-leading "could not complete service restart".
The ProxyLogger must only be set after mainLog is fully initialized.
However, it's being set before the final initialization of mainlog,
causing it still refers to stale old pointer.
To fix this, introduce a new function to discard ProxyLogger explicitly,
and use this function to init logging for all interactive commands.
copy
fix get valid ifaces in nameservers_bsd
nameservers on MacOS can be found in resolv.conf reliably
nameservers on MacOS can be found in resolv.conf reliably
exclude local IPs from MacOS resolve conf check
use scutil for MacOS, simplify reinit logic to prevent duplicate calls
add more dns server fetching options
never skip OS resolver in IsDown check
split dsb and darwin nameserver methods, add delay for setting DNS on interface on network change.
increase delay to 5s but only on MacOS
set service on new run, fix duplicate args
set service on new run, fix duplicate args
revert startCmd in upgrade flow due to pin compat issues
make restart reset DNS like upgrade, add debugging to uninstall method
debugging
debugging
debugging
debugging
debugging WMI
remove stackexchange lib, use ms wmi pkg
debugging
debugging
set correct class
fix os reolver init issues
fix netadapter class
use os resolver instead of fetching default nameservers while already running
remove debug lines
fix lookup IP
fix lookup IP
fix lookup IP
fix lookup IP
fix dns namserver retries when not needed
debugging
skip type 24 in nameserver detection
skip type 24 in nameserver detection
remove interface type check from valid interfaces for now
skip non hardware interfaces in DNS nameserver lookup
ignore win api log output
set retries to 5 and 1s backoff
reset DNS when upgrading to make sure we get the proper OS nameservers on start
init running iface for upgrade
update windows service options for auto restarts on failure
make upgrade use the actual stop and start commands
fix the windows service retry logic
fix the windows service retry logic
task debugging
more task debugging
windows service name fix
windows service name fix
fix start command args
fix restart delay
dont recover from non crash failures
fix upgrade flow
Since these are the interfaces that ctrld will manipulate anyway.
While at it, also skipping non-working devices on MacOS, by checking
if the device is present in network service order
smol tweaks to nameserver test queries
fix restoreDNS errors
add some debugging information
fix wront type in log msg
set send logs command timeout to 5 mins
when the runningIface is no longer up, attempt to find a new interface
prefer default route, ignore non physical interfaces
prefer default route, ignore non physical interfaces
add max context timeout on performLeakingQuery with more debug logs
Since ctrld process does not rely on the global variable iface anymore
during runtime, ctrld client's operations must be updated to reflect
this change, too.