Known Issues

This document outlines known issues with ctrld and their current status, workarounds, and recommendations.

macOS (Darwin) Issues

Self-Upgrade Issue on Darwin 15.5

Issue: ctrld self-upgrading functionality may not work on macOS Darwin 15.5.

Status: Under investigation

Description: Users on macOS Darwin 15.5 may experience issues when ctrld attempts to perform automatic self-upgrades. The upgrade process would be triggered, but ctrld won't be upgraded.

Workarounds:

  1. Recommended: Upgrade your macOS system to Darwin 15.6 or later, which has been tested and verified to work correctly with ctrld self-upgrade functionality.
  2. Alternative: Run ctrld upgrade prod directly to manually upgrade ctrld to the latest version on Darwin 15.5.

Affected Versions: ctrld v1.4.2 and later on macOS Darwin 15.5

Last Updated: 05/09/2025


Merlin Issues

Daemon Crashing on Ctrl+C

Issue: ctrld daemon terminates unexpectedly after stopping a log tailing command. This typically occurs when running the daemon and the log viewer within the same SSH session on ASUSWRT-Merlin routers.

Description

The issue is caused by Signal Propagation within a shared Process Group (PGID).

Steps to reproduce:

  1. You start the daemon manually: ctrld start --cd=<uid>.
  2. You view internal logs in the same terminal: ctrld log tail.
  3. You press Ctrl+C to stop viewing logs.
  4. The ctrld daemon service stops immediately along with the log command.

When you execute commands sequentially in a single interactive SSH session on Merlin, the shell often assigns them to the same Process Group. In Linux, the SIGINT signal (triggered by Ctrl+C) is not just sent to the foreground application, but is frequently propagated to every process belonging to that specific process group.

Because the ctrld daemon remains "attached" to the terminal session's process group, it "hears" the interrupt signal intended for the log tail command and shuts down.

Workarounds:

To isolate the signals, avoid running the log viewer in the same window as the daemon:

  • Window A: Start the daemon and leave it running.
  • Window B: Open a new SSH connection to run ctrld log tail. Because Window B has a different Session ID and Process Group ID, pressing Ctrl+C in Window B will not affect the process in Window A.

Contributing to Known Issues

If you encounter an issue not listed here, please:

  1. Check the GitHub Issues to see if it's already reported
  2. If not reported, create a new issue with:
    • Detailed description of the problem
    • Steps to reproduce
    • Expected vs actual behavior
    • System information (OS, version, architecture)
    • ctrld version

Issue Status Legend

  • Under investigation: Issue is confirmed and being analyzed
  • Workaround available: Temporary solution exists while permanent fix is developed
  • Fixed: Issue has been resolved in a specific version
  • Won't fix: Issue is acknowledged but will not be addressed due to technical limitations or design decisions