### [CVE-2017-8414](https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2017-8414)
![](https://img.shields.io/static/v1?label=Product&message=n%2Fa&color=blue)
![](https://img.shields.io/static/v1?label=Version&message=n%2Fa&color=blue)
![](https://img.shields.io/static/v1?label=Vulnerability&message=n%2Fa&color=brighgreen)
### Description
An issue was discovered on D-Link DCS-1100 and DCS-1130 devices. The binary orthrus in /sbin folder of the device handles all the UPnP connections received by the device. It seems that the binary performs a sprintf operation at address 0x0000A3E4 with the value in the command line parameter "-f" and stores it on the stack. Since there is no length check, this results in corrupting the registers for the function sub_A098 which results in memory corruption.
### POC
#### Reference
- http://packetstormsecurity.com/files/153226/Dlink-DCS-1130-Command-Injection-CSRF-Stack-Overflow.html
#### Github
- https://github.com/ethanhunnt/IoT_vulnerabilities